9.

Carefully install the new lamp. Leave the golden side down towards the interior of the module; when
correctly installed, the internal wires of the lamp are visible.

NOTE:

The lamp is symmetrical lengthwise and both orientations are correct.

10.

Rotate the latches back to the normal position and insert the screws.

11.

Connect the cables of the new lamps. There is no mandatory orientation of the cables (top or bottom).

12.

Ensure that the fast-on connectors are well assembled. Push them into the ‘click’ position for proper
retention. Check that the plastic insulation covers the whole terminal after assembly.

13.

Add and screw in both clamps.

Clean the drying quartz glass and the air outlet

1.

Take the drying quartz glass and air outlet, which you have already removed.