Replace the drying fans array – HP Latex 3000 Printer User Manual

Page 219

Advertising
background image

7.

Remove the aerosol fan module and insert the new one.

8.

Put the hinges back in place, put back the nuts and tighten them.

9.

Open the new aerosol fan cover.

10.

Remove the three screws that attach the new fan cover, and remove the cover.

11.

Connect the two aerosol fan cable connectors.

12.

Route the main cable harness and insert the grommet in the cover slot. Make sure the cables are not
tight inside the cover.

13.

Install the aerosol fan cover and attach the three screws.

14.

Close the cover.

Finish off replacing the aerosol fan module

1.

Close the service position window.

CAUTION:

Do not leave anything in the way of the carriage.

2.

Turn on the printer in the correct way for maintenance operations: see

Turn the printer on on page 143

.

3.

Run a diagnostic test to check that the aerosol fans are working correctly.

4.

Dispose of the old aerosol module fans.

Replace the drying fans array

Risk of burns

Crush hazard

Risk of trapped

fingers

Hazardous moving

part

Light radiation hazard

Electric shock hazard

For more safety information, see

Safety precautions on page 2

ENWW

Replace the drying fans array 213

Advertising