Air supply requirements (pneumatic spindle), Air pressure supply, Pneumatic connector – HP Latex 3000 Printer User Manual

Page 302: Ecological specifications, Environmental specifications

Advertising
background image

Mains power, input rated current

3-phase (line-to-line voltage): 200–240 V AC (±10%), 50/60 Hz, 48 A max; or

3-phase (line-to-line voltage): 380–415 V AC (±10%), 50/60Hz, 30 A max; or

High-current 1-phase: 240 V AC (±10%), 50/60Hz, 63 A max

PC power (optional), input rated current

1-phase: 100–127 V AC (±10%), 50/60Hz, 6 A max

1-phase: 200–240 V AC (±10%), 50/60Hz, 6 A max

Air supply requirements (pneumatic spindle)

Air pressure supply

The pneumatic spindle requires an air compressor or a pressurized air line, not supplied with the printer.

TIP:

You are recommended to use a pressure gauge that indicates the pressure in bars.

Table 14-7

Air supply specifications

Air pressure

5.5 bar (80 psi)

Minimum airflow

Recommendation: 30 l/min

Lubricator

Not recommended

Air filter (recommended)

Recommendation: 5 µm, auto-drain, 99.97% coalescing efficiency

Regulator (required)

Regulator with pressure gauge

Pneumatic connector

The printer comes with an air gun that you must attach to your air supply. In order to connect your air supply
to the air gun, you must meet the following requirements:

9.84-mm (0.25-in) female connector, BSP or NPT thread

Tape to secure the connection and prevent air leaks

Ecological specifications

For the up-to-date ecological specifications of your printer, go to

http://www.hp.com/

and search for

“ecological specifications”.

Environmental specifications

Table 14-8

Printer environmental specifications

Temperature range

Humidity range

Temperature gradient

Operating for optimal print
quality

20 to 25°C (68 to 77°F)

30 to 60% relative humidity

10°C/h (18°F/h) or less

Operating for standard printing

15 to 30°C (59 to 86°F)

20 to 70% relative humidity

10°C/h (18°F/h) or less

296 Chapter 14 Printer specifications