4.

Pull the drying module carefully out of the carriage and lay it gently on a table.

Replace the drying quartz glass

1.

To separate the drying glass and air outlet from the rest of the module, remove the three screws shown
below.

2.

Assemble the drying lamps section and the new drying glass and air outlet.

3.

Insert the three screws.

Reinstall the drying module

1.

Reinstall the drying module into the carriage and tighten the three screws that attach it to the carriage.

ENWW

Replace the drying quartz glass 221