Replace the drying quartz glass – HP Latex 3000 Printer User Manual

Page 224

Advertising
background image

5.

Put back the screw that you removed earlier.

6.

Reconnect the drying fans array connector.

7.

Reinstall the drying filter.

Reinstall the drying module

1.

Reinstall the drying module into the carriage and tighten the three screws that attach it to the carriage.

2.

Reconnect the electrical connector and close the latches.

Finish off replacing the drying fans array

1.

Close the service position window.

CAUTION:

Do not leave anything in the way of the carriage.

2.

Turn on the printer in the correct way for maintenance operations: see

Turn the printer on on page 143

.

3.

Dispose of the old drying fans array according to local regulations.

Replace the drying quartz glass

218 Chapter 8 Hardware maintenance

ENWW