Table 10 SNMP traps

Description

SNMP trap name

SNMP has been initialized, the system has completed POST, or
AMS has started.

Cold Start Trap 0

SNMP has detected an authentication failure.

Authentication Failure Trap 4

A change has been detected in the status of the Smart Array
controller.

cpqDa6CntlrStatusChange 3033

A change has been detected in the status of a Smart Array logical
drive.

cpqDa6LogDrvStatusChange 3034

A change has been detected in the status of a Smart Array cache
module.

cpqDa6AccelStatusChange 3038

The Smart Array cache module has lost backup power.

cpqDa6AccelBadDataTrap 3039

The Smart Array cache module backup power has failed.

cpqDa6AccelBatteryFailed 3040

A change has been detected in the status of a Smart Array physical
drive.

cpqDa7PhyDrvStatusChange 3046

A change has been detected in the status of a Smart Array spare
drive.

cpqDa7SpareStatusChange 3047

A change has been detected in the SSD wear status of a Smart
Array physical drive.

cpqDaPhyDrvSSDWearStatusChange 3049

The server was shut down due to a thermal anomaly and is now
operational.

cpqHe3ThermalConfirmation 6026

One or more POST errors have occurred.

cpqHe3PostError 6027

The fault-tolerant power supplies have lost redundancy for the
specified chassis.

cpqHe3FltTolPowerRedundancyLost 6032

A fault-tolerant power supply has been inserted.

cpqHe3FltTolPowerSupplyInserted 6033

A fault-tolerant power supply has been removed.

cpqHe3FltTolPowerSupplyRemoved 6034

The fault-tolerant fan condition has been set to Degraded.

cpqHe3FltTolFanDegraded 6035

The fault-tolerant fan condition has been set to Failed.

cpqHe3FltTolFanFailed 6036

The fault-tolerant fans have lost redundancy.

cpqHe3FltTolFanRedundancyLost 6037

A fault-tolerant fan has been inserted.

cpqHe3FltTolFanInserted 6038

A fault-tolerant fan has been removed.

cpqHe3FltTolFanRemoved 6039

The temperature status has been set to Degraded, and the
temperature is outside the normal operating range. Depending
on the system configuration, this system might be shut down.

cpqHe3TemperatureDegraded 6041

The temperature status has been set to OK.

cpqHe3TemperatureOk 6042

The fault-tolerant power supply condition has been reset to OK.

cpqHe4FltTolPowerSupplyOk 6048

The fault-tolerant power supply condition has been set to Degraded.

cpqHe4FltTolPowerSupplyDegraded 6049

The fault-tolerant power supply condition has been set to Failed.

cpqHe4FltTolPowerSupplyFailed 6050

The Advanced Memory Protection subsystem has detected a
memory fault. Mirrored Memory has been activated.

cpqHeResilientMemMirroredMemoryEngaged 6051

The fault-tolerant power supplies have returned to a redundant
state.

cpqHe3FltTolPowerRedundancyRestore 6054

The fault-tolerant fans have returned to a redundant state.

cpqHe3FltTolFanRedundancyRestored 6055