NOTE:

The current implementation of the iLO Virtual Serial Port does not use a physical

UART, so the BIOS Serial Console Baud Rate value will have no effect on the actual speed
the iLO Virtual Serial Port will use to send and receive data from the system.

14. Press ESC to return to the main menu.
15. Select EMS Console, and then press Enter.
16. Select the COM port that matches the value selected in

step 6

, and then press Enter, as shown

in

Figure 114 (page 212)

.

Figure 114 Configuring the EMS Console (UEFI System Utilities)

17. Press F10 to save the changes.

The iLO 4 Configuration Utility prompts you to confirm that you want to save all pending
configuration changes.

18. Press Enter.

The iLO 4 Configuration Utility notifies you that iLO must be reset in order for the changes to
take effect.

19. Press Enter.

iLO resets, and the remote console session is automatically ended. You can reconnect in
approximately 30 seconds.

20. Resume the normal boot process:

a.

Start the iLO remote console.

The iLO 4 Configuration Utility is still open from the previous session.

b.

Press ESC several times to navigate to the System Configuration page.

c.

Press ESC to exit the System Utilities and resume the normal boot process.