The RAID status is located at the top of the RAID Setup tab in Storage. RAID status also appears
in the Details tab on the main CMC window when a storage system is selected in the navigation
window.

Figure 10 Monitoring RAID status on the main CMC window

1. RAID status

The status displays one of five RAID states.

Normal—RAID is synchronized and running. No action is required.

Rebuilding—A new disk has been inserted in a drive bay, or a hot spare has been activated,
and RAID is currently rebuilding. No action is required.

Degraded—RAID is degraded. A disk may have failed or have been removed from its bay.

For hot-swap storage systems, simply replace the faulty, inactive, uninitialized, or missing disk.

Off—Data cannot be stored on the storage system. The storage system is offline and flashes
in the navigation window.

None—RAID is unconfigured.

Managing disks

Use the Disk Setup tab to monitor disk information and perform disk management tasks as listed
in

Table 9 (page 28)

.

Table 9 Disk management tasks for storage systems

Where available

Disk setup function

All storage systems

Monitor disk information

Storage systems running version 9.5.01 or later

View Disk Details

Storage systems with this capability

Activate Drive ID LEDs

Storage systems with this capability

Add disk to RAID and set Auto Tiering

Getting there

1.

In the navigation window, select a storage system.

2.

Select the Storage category in the tree below it.

3.

Click the Disk Setup tab.

Reading the disk report on the Disk Setup tab

The Disk Setup tab provides a status report of the individual disks in a storage system.

Figure 11 (page 29)

shows the Disk Setup tab and

Table 10 (page 29)

describes the corresponding

disk report.