The tcp/ip tab, Identifying the network interfaces, Pinging an ip address – HP LeftHand P4000 SAN Solutions User Manual

Page 51: To ping an ip address

Advertising
background image

6.

Change the flow control setting on the Edit window.

7.

Click OK.

8.

Repeat these steps for all the NICs you want to change.

On the TCP Status tab window, for bonded NICs, the NIC flow control column shows the flow
control settings for the physical NICs, and the bond0 as blank. Flow control is enabled and working
in this case

The TCP/IP tab

Lists the network interfaces on the storage system. On the TCP/IP tab, you can bond interfaces,
disable an interface, configure an IP address, and ping servers from the storage system.

Identifying the network interfaces

A storage system comes with up to six Ethernet interfaces. To configure the first interface when
configuring a new storage system, you must connect an Ethernet cable to one of the storage system’s
serial ports, or attach a keyboard and mouse to a USB port, and configure the interface in the
Configuration Interface, as described in

“Using the Configuration Interface” (page 247)

. These ports

are named and labeled on the back of the storage system. Once the storage system has an IP
address and can be located using the Find feature in the CMC, you can work with all the NICs in
the CMC or through the Configuration Interface.

Table 15 (page 51)

lists the methods to identify the NICs.

Table 15 Identifying the network interfaces on the storage system

Ethernet interfaces

Label

Where labeled

Name of the interface. Entries vary depending on the storage system.

In the Network configuration
category in the CMC

eth0, eth1

TCP/IP tab

Motherboard:Port1, Motherboard:Port2

TCP Status tab

BladeBoard:Port1, BladeBoard:Port2

FlexLOM:Port1, FlexLOM:Port2

NICSlot1:Port1, NICSlot1:Port2

For bonded interfaces:

bond0, bond1

In the Configuration Interface
available through the storage
system’s serial port

Intel Gigabit Ethernet

Broadcom Gigabit Ethernet

On the label on the back of the
storage system

eth0, eth1

Represented by a graphical symbol similar to the symbols below:

or

Pinging an IP address

Because the SAN should be on a private network, you can ping target IP addresses from a storage
system using the CMC. You can ping from any enabled interface listed on the TCP/IP tab. You
can ping any IP address, such as an iSCSI server or a Fibre Channel switch.

To ping an IP address

1.

Select a storage system, and open the tree below it.

2.

Select Network.

The TCP/IP tab

51