Creating a nic bond – HP LeftHand P4000 SAN Solutions User Manual

Page 63

Advertising
background image

Figure 40 Adaptive Load Balancing in a two-switch topology

1. Servers

2. HP StoreVirtual Storage systems

3. Storage cluster

4. GigE trunk

Creating a NIC bond

IMPORTANT:

You cannot bond the virtual NICs in a StoreVirtual VSA.

Follow these guidelines when creating NIC bonds:

Prerequisites

Verify that the speed, duplex, flow control, and frame size are all set properly on both interfaces
that are being bonded. These settings cannot be changed on a bonded interface or on either of
the supporting interfaces.

For detailed instructions about properly configuring these settings, see

“Managing settings on

network interfaces” (page 47)

.

Bond guidelines

Create a bond on a storage system before you add the storage system to a management
group.

Create bonds of two interfaces.

An interface can only be in one bond.

Record the configuration information of each interface before you create the bond. Then, if
you delete the bond, you can return to the original configuration if desired.

When you delete an Active-Passive bond, the preferred interface assumes the IP address
and configuration of the deleted logical interface.

When you delete a Link Aggregation Dynamic Mode or an Adaptive Load Balancing
bond, one of the interfaces retains the IP address of the deleted logical interface. The
IP address of the other interface is set to 0.0.0.0.

Configuring network interface bonds

63