Heater preset temperature by medium – HP Designjet 9000s Printer series User Manual

Page 181

Advertising
background image

Front panel display (when the heater is turned on):

Upper line: preset temperature for each heater

Lower line: current temperature for each heater

Front panel display (when the heater is turned off):

Upper line: OFF for each heater

Lower line: current temperature for each heater

The default temperature range is set between 15 °C and 55 °C.

Heater preset temperature by medium

The heater preset temperature for each media type is listed below. Preset the heater temperature
according to the media you use.

Medium

Media type

Front

Print

Rear

Print mode

Glossy vinyl
chloride

Glossy

45°C

40°C

45°C

4-pass
bidirectional

Matte vinyl
chloride

Matte

45°C

40°C

45°C

4-pass
bidirectional

Banner

Banner

45°C

40°C

45°C

4-pass
bidirectional

We recommend that the front heater, the print heater and the rear heater be set to lower than 50 °C, 45 °
C and 50 °C, respectively. When the print heater is set to higher than 45 °C, we recommend setting the
printhead motion mode to HIGHLIGHT.

NOTE When the print heater temperature is set too high, fixing of the ink on the media is
improved, but media wrinkle or mat print may be caused. Adjust heater temperature according
to the media type and environmental temperature.

When the print heater temperature is set to high, the printer may print at low speed to ensure
stable print quality.

Set the front/rear heater temperature 5 °C higher than the print heater temperature. Bad
temperature balance between the front/rear heater and print heater may cause the media to
wrinkle.