HEAT Starting/Stopping the Optional Heater

Syntax:

HEAT ON/OFF<cr>

Example:

>heat
Heat : OFF
>
>heat on
Heat : ON
>
>heat off
Heat : OFF
>

SALT Enables/Disables the Salt Contamination
Detection

Syntax:

SALT ON/OFF [interval]<cr>

Default: SALT ON

Example:

>salt
Salt sensing : OFF 24
>

Salt sensing is off.

>salt on
Salt sensing : ON 24
>

Salt sensing is on and detection interval is 24 h.

>salt 30
Salt sensing : ON 30 <cr><lf>
>

Salt sensing is on and detection interval is 30 h.

>salt on 24
Salt sensing : ON 24
>

Salt sensing is on and detection interval is 24 h.