AT-IFS802SP/POE(W)-80 User Manual

SMTP Configuration interface

Having ticked the

Syslog/SMTP checkboxes, the event log/email alert will be sent to the system log

server and the SMTP server respectively. Also, Port event log/alert (link up, link down, and both) can
be sent to the system log server/SMTP server respectively by setting the trigger condition.

System event selection

: There are 4 event types—Device Cold Start, Device Warm Start,

Authentication Failure, and X-ring Topology Change. The checkboxes are not available for ticking
unless the

Syslog Client Mode on the Syslog Configuration tab and the E-mail Alert on the

SMTP Configuration tab are enabled first.

Device cold start: When the device executes cold start action, the system will issue the event log/
email alert to the system log/SMTP server respectively.
Device warm start: When the device executes warm start, the system will issue the event log/email
alert to the system log/SMTP server respectively.
Authentication Failure: When the SNMP authentication fails, the system will issue the event log/
email alert to the system log/SMTP server respectively.
X-ring topology change: When the X-ring topology has changed, the system will issue the event
log/email alert to the system log/SMTP server respectively.

6.8.3 System Event Log - Event Configuration

>

>

>

>