HW-G Instruction Manual Page 21

HW-G OZIM v1a

Counting Mode

8 Counting Mode

In counting mode the total weight of articles is converted to a count and assumes
all articles have the same mass value.

It is necessary to store a unit mass to count articles.

8.1 Storing a Unit Mass

Step 1 Press the

MODE

switch to display the unit

PCS

.

Step 2 Press the

SET

switch to enter the mode to store

a unit mass.

Step 3 Press the

^

switch to select the number of

samples. The greater the quantity of samples, the
greater the accuracy of the count. Select from
5 pieces, 10 pieces, 20 pieces, 50 pieces, 100
pieces

Step 4 Put the container onto the pan.

Press the

TARE

switch.

Step 5 Put in the number of samples selected at step 3.

Press the

ENTER

switch to store the weight after

the stability mark is displayed. The count is then

displayed.
Caution
When the sample is too light and it is not

possible to

calculate a unit mass, the scale displays

lo ut

and

returns to step 3. It is necessary to increase the
number of samples.
Pressing the

ENTER

switch after the

lo ut .

is

displayed, the next unit is displayed.
When the unit mass is too light to store, the scale
displays

lo ut .

Step 4

Remove all items from the pan.

Advertising