15.2 Parameter List

Item

Display

Meaning and purpose

?

The type L scale is turned off after 5 minutes of no operation,
when displaying zero.

Automatic

f1 0

#

Not used

?

turning off

f1 1

Used

?

?

Transmission rate of the serial interface (RS-232C/ 422/485).

f4 0

#

2400bps

?

Baud rate

f4 1

4800bps

?

f4 2

9600bps

?

Mode selection for the serial interface (RS-232C/ 422/485).

f5 0

#

Stream mode. (Refer to “16.2 Stream Mode”)

?

f5 1

Command mode. (Refer to “16.3 Command Mode”)

?

f5 2

A data is output, when the

PRINT

switch is pressed.

?

f5 3

Auto-print +
When the display becomes a positive stable value above
near-zero, the scale outputs the data automatically. Next

Output mode

output can be performed after the display becomes near-
zero or a negative value.

?

?

f5 4`

Auto-print +/-
When the display becomes a stable value outside near-zero,
the scale outputs the data automatically. Next output can be
performed after the display becomes near-zero.

?

?

f5 5

At each finish of full/dribble batch function, the data is output.

?

Mode selection for the comparator

f6 0

#

Pressing the

SET

switch, the scale always compares the

current display value.

A

A

f6 1

The scale always compares the display value.

A

Comparator

f6 2

Pressing the

SET

switch, the scale always compares the

display value when not near-zero.

A

f6 3

The scale always compares the display value when not

near-zero.

A

Notes
The “#” shows factory settings.
The “near-zero” is within

±

4 digits from zero point in the unit of kg.