2 operation and performance (examples), Example 1, Example 2 – A&D Digital Platform Scales HW-10KGV User Manual

Page 29

Advertising
background image

HW-G Instruction Manual Page 27

HW-G OZIM v1a

10.2 Operation and Performance (Examples)

Example 1

Weighing each article, the scale makes the accumulation according to

f8 3

.

Step 1 Press the

MODE

switch to display

M+

or

.

Step 2 Press the

ZERO

switch to reset the accumulation data.

Step 3 Return to the kg mode using the

MODE

switch.

Press the

ZERO

switch with nothing on the pan.

Step 4 Put an article on the pan. Wait for the stability mark to be displayed and the

value to blink. Remove the article and, if necessary, press the

ZERO

switch.

Step 5 Weigh additional articles using step 4.

Step 6

Press the

MODE

switch to display the number of articles and total mass with

M+

or

displayed.

Example 2

This example accumulates the articles that were removed from the pan. The
function parameter is set to

f8 4

.

Step 1 Enter into the kg mode using the

MODE

switch.

Put all articles on the pan and press the

TARE

switch.

Step 2 Press the

MODE

switch to display

M+

or

.

Step 3 Press the

ZERO

switch to reset the accumulation data.

Retun to kg mode with the

MODE

switch.

Step 4 Remove an article from the pan. Wait for the stability mark to be displayed and

the value to be blinking. Press the

TARE

switch.

Step 5 Remove additional articles using step 4.

Step 6 Press the

MODE

switch to display the number of articles and total mass

removed, with

M+

or

displayed.

Advertising