HW-G OZIM v1a

This function counts the number of weighed items, calculates the total mass value and
can display the number and accumulated mass value.

It is necessary to set the parameters of the “accumulation function (

f8

)” in the function

table in advance to use this function.

It is necessary to set the parameters of the “print mode (

f9

)” in the function table in

advance to use the optional built-in printer.

Operation and Switches

The display of the accumulation count has a blinking

M+

or

without a unit.

The display of the accumulation value has a blinking

M+

kg or

kg with a unit.

Pressing the

MODE

switch, the accumulation count and accumulation value is displayed.

Pressing the

ZERO

switch in the accumulation function while a blinking

M+

or

is

displayed, resets the current function. The count and accumulated value become zero.

When the optional built-in printer is installed and the

PRINT

switch is pressed, the

accumulation data, date and data number are printed. Date is set at function table

f16

.

Caution

The accumulation function can only be used with the first weighing unit
accumulated, e.g. you cannot accumulate pcs while displaying kg.

Parameter List and Word Definition

The “near-zero” is within

±

4 digits from the zero point in the unit of kg.

The “digit”, a unit of display, is equivalent to the minimum graduation.
The “zero point” is the fundamental starting point to weighing.

Function table

Meaning & Purpose

f8 0

Accumulation function not used.
The scale accumulates the data, if the

F

switch is pressed when

the display is a positive stable value above near-zero. The next

f8 1

accumulation can be performed after the display returns to
near-zero or to a negative value.

f8 2

The scale accumulates the data, if the

F

switch is pressed, when

the display is a stable value and outside near-zero. The next
accumulation can be performed after the display returns to
near-zero.

f8 3

When the display is a positive stable value, the scale accumulates
the data automatically. The next accumulation can be performed
after the display returns to near-zero or to a negative value.

10 Accumulation Function