HW-G Instruction Manual Page 31

HW-G OZIM v1a

11.2 Operation and Performance (Examples)

Example 1

This example is set as follows:
Function table

f6 3

(If the current display value is not near-zero,
the scale compares the display value with the
upper limit value and the lower limit value
immediately.)

Upper limit value (HI)

7.000kg

Lower limit value (LO)

6.500kg

Case

The comparison starts at turning the scale on.
When the current value is less than 6.500kg, LO is displayed.
When the current value is between 6.500kg and 7.000kg, OK is displayed.
When the current value is greater than 7.000kg, HI is displayed.

Example 2

This example is set as follows:
Function table

f6 4

(Pressing the

SET

switch, after the stability

mark is displayed, the scale compares the
current display value with the upper limit value
and the lower limit value immediately.)

Upper limit value (HI)

2.000kg

Lower limit value (LO)

-1.000kg

Case

Pressing the

SET

switch, after displaying the stability mark ,the comparison is

performed.

When the current value is less than -1.000kg, LO is displayed.

When the current value is between -1.000kg and 2.000kg, OK is displayed.

When the current value is greater than 2.000kg, HI is displayed.