Troubleshooting Parameters

A-246

41-001160-03, Rev 00, Release 2.4

IP Phone Administrator Guide

Range

Examples

Enter a debug level value in the “Debug Level” field for a module.

Example 1

To turn two or more debug levels on at the same time, you add the value
associated with each level. For example,

Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7

log module linemgr: 7
log module user interface: 7
log module sip: 7

In the above example, fatal errors, general errors, and warnings are
logged for the line manager, user interface, and SIP call control modules.

Example 2

Functions and Info = 16 + 32 = 48

log module dis: 48
log module net: 48
log module snd: 48

In the above example, functions and general information are logged for
the display drivers, network, and sound modules.

Example 3

log module rtpt: 0
log module ind: 65535

In the above example, all debug levels are OFF for the Real Time
Transport module. All debug levels are ON for the indicator module.
You can set the Module/Debug Levels using the configuration files or the
Aastra Web UI.

Debug Level

Value

Fatal Errors

1 (default)

Errors

2

Warnings

4

Init

8

Functions

16

Info

32

All debug

levels OFF

0

All Debug

Levels ON

65535