ARI* CAPACITY RATINGS — 580F036-151

LEGEND

*Air Conditioning and Refrigeration Institute.

†Applies only to units with capacity of 65,000 Btuh or less.

**The IPLV applies only to two-stage cooling units.
NOTES:

1. Rated in accordance with ARI Standards 210/240 (for sizes 036-

120) or 360, (for size 150 and 151) and 270.

2. ARI ratings are net values, reflecting the effects of circulating fan

heat.

3.

Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air tempera-
ture and 95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature
and 80 F db outdoor entering-air temperature.

4.

All 580F036, 048, 060, 073, 091, 103, 121, 151 units are in com-
pliance with ASHRAE 90.1-1999 Energy Standard for minimum
SEER and EER requirements. Refer to state and local codes or
visit the following website: http://bcap-energy.org to determine if
compliance with this standard pertains to a given geographical
area of the United States.

HEATING CAPACITIES AND EFFICIENCIES (Standard-Efficiency Units) — 580F036-151

208/230-1-60 — SINGLE-STAGE GAS HEAT

208/230-1-60 — SINGLE-STAGE GAS HEAT — LOW NOx

UNIT 580F

NOMINAL

TONS

STANDARD

CFM

NET COOLING

CAPACITY

(Btuh)

TOTAL

kW

SEER†

SOUND

RATING

(dB)

Belt Drive

Direct Drive

036

3

1200

35,000

4.0

10.0

9.7

81

048

4

1600

47,000

5.3

10.0

9.7

81

060

5

2000

57,000

6.7

10.0

9.7

81

UNIT
580F

NOMINAL

TONS

NET COOLING

CAPACITY

(Btuh)

TOTAL

kW

EER

SOUND

RATING

(dB)

IPLV

072

6

72,000

8.0

9.0

81

**

073

6

71,000

7.0

10.1

80

**

090

7

1

/

2

85,000

9.6

8.9

87

9.40

091

7

1

/

2

88,000

8.7

10.1

82

10.5

103

8

1

/

2

100,000

9.9

10.1

82

10.4

120

10

117,000

13.0

9.0

88

9.40

121

10

114,000

11.3

10.1

84

11.0

150

12

1

/

2

144,000

16.0

9.0

87

9.20

151

12

1

/

2

136,000

14.3

9.5

86

9.70

dB

Sound Levels (decibels)

db

Dry Bulb

EER

Energy Efficiency Ratio

IPLV

Integrated Part-Load Values

SEER — Seasonal Energy Efficiency Ratio
wb

Wet Bulb

UNIT
580F

INPUT

CAPACITY

OUTPUT

CAPACITY

TEMPERATURE

RISE (°F)

MINIMUM HEATING

AIRFLOW (CFM)

EFFICIENCY

AFUE (%)

Steady State (%)

036074

74,000

57,000

25-55

1004

80

80

036115

115,000

89,000

55-85

1002

80

80

048074

74,000

57,000

25-55

1004

80

80

048115

115,000

91,000

35-65

1327

80

80

048150

150,000

118,000

50-80

1396

80

80

060074

74,000

57,000

25-55

1004

80

80

060115

115,000

91,000

35-65

1327

80

80

060150

150,000

118,000

50-80

1314

80

80

UNIT
580F

INPUT

CAPACITY

OUTPUT

CAPACITY

TEMPERATURE

RISE (°F)

MINIMUM HEATING

AIRFLOW (CFM)

EFFICIENCY

AFUE (%)

Steady State (%)

036060N

60,000

49,000

20-50

910

80

80

036090N

90,000

73,000

30-60

1130

80

80

048060N

60,000

49,000

20-50

910

80

80

048090N

90,000

73,000

30-60

1130

80

80

048120N

120,000

98,000

40-70

1300

80

80

060060N

60,000

49,000

20-50

910

80

80

060090N

90,000

73,000

30-60

1130

80

80

060120N

120,000

98,000

40-70

1300

80

80