FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

12

All electrical systems have the potential to

cause sparks during service. Take care to

eliminate explosive or hazardous environments

during service and/or repair.

To prevent system damage or electrical

shock the main power supply wire is the last

connection made to the Hale Foam proportioner

distribution box.

Release all pressure then drain all concentrate

and water from the system before servicing any

of its component parts.

Do not operate system at pressures higher than

the maximum rated pressure.

Use only pipe, hose, and fittings from the foam

pump outlet to the injector fitting, which are rated

at or above the maximum pressure rating at

which the water pump system operates.

Hale Foam proportioning systems are designed

for use on negative ground direct current

electrical systems only.

Do not mount radio transmitter or transmitter

cables in direct or close contact with the

FoamLogix control unit.

Before connecting the cord sets and wiring

harnesses, inspect the seal washer in the female

connector. If the seal washer is missing or

damaged, water can enter the connector causing

corrosion of the pins and terminals. This could

resulting in possible system failure.

Always disconnect the power cable, ground

straps, electrical wires and control cables from

the control unit or other Hale Foam system

equipment before electric arc welding at any

point on the apparatus Failure to do so could

result in a power surge through the unit that

could cause irreparable damage.

DO NOT connect the main power lead to small

leads that are supplying some other device, such

as a light bar or siren.

The Hale FoamLogix, Models 2.1A and

1.7AHP require 40 AMP minimum current.

When operating the Hale FoamLogix in

Simulated Flow mode, an outlet for the foam

concentrate must be provided to prevent

excessive pressure buildup in the discharge

piping or hoses.

Make sure the foam tank and foam concentrate

suction hoses are clean before making final

connection to foam pump. If necessary flush

tank and hoses prior to making connection.

Check all hoses for weak or worn conditions

after each use. Ensure that all connections and

fittings are tight and secure.

Ensure that the electrical source of power for

the unit is a negative (–) ground DC system, of

correct input voltage, with a reserve minimum

current available to drive the system.

The in-line strainer/valve assembly is a low

pressure device and WILL NOT withstand

flushing water pressure in excess of 45 PSI (3

BAR).

When determining the location of Hale Foam

system components keep in mind piping runs,

cable routing and other interferences that

could hinder or interfere with proper system

performance.

Always position the check valve/injector fitting

at a horizontal or higher angle to allow water

to drain away from the fitting. This avoids the

possibility of sediment deposits or the formation

of an ice plug.

The cord sets provided with each Hale Foam

system are indexed to ensure correct receptacle

installation (they insert one way only). When

making cord set connections DO NOT force

mismatched connections as damage can result

in improper system operation.

Make sure all connections are sound, and that

each connection is correct.

The cables shipped with each Hale Foam

system are 100% tested at the factory with that

unit. Improper handling and forcing connections

can damage these cables which could result in

other system damage.