Foam Pump Mounting

Position the foam pump and motor assembly in the

desired location on the apparatus. When installing

the foam pump and motor assembly, the assembly

should be kept in a HORIZONTAL position with the

base plate on the bottom (See Figure 7: “FoamLogix

Pump Installation.”)

Figure 7: FoamLogix Pump Installation

Although the system is sealed and designed to be

resistant to the harsh environment of fire fighting

apparatus, a compartment with easy operator

access is recommended.

The base plate of the foam pump and motor

assembly must be anchored to a surface or structure

that is rigid and of adequate strength to withstand

the vibration and stresses of apparatus operation.

Figure 8: “Base Plate Mounting Hole Locations,” on

page 35, provides the mounting base dimensions

for the FoamLogix foam pump and motor assembly.

Make sure the foam concentrate hoses are properly

routed to the inlet and outlet on the foam pump.

Foam concentrate must gravity feed to the foam

pump inlet from the foam tank(s). The foam pump

must be mounted in an area to avoid excessive

engine exhaust system heat or acces sory heat

buildup.

The base of the foam pump and motor assembly

includes 5/16” (8mm) diameter predrilled mount ing

holes. The apparatus mounting location must to be

drilled accordingly. The base plate may be used as

a template to mark mounting hole loca tion. Also see

Figure 8: “Base Plate Mounting Hole Locations” on

page 35.