Start-up checklist – Class1 FoamLogix 2.1A & 1.7AHP REV D User Manual

Page 48

Advertising
background image

FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

48

START-UP CHECKLIST

Before energizing the apparatus and Hale Foam-

Logix system for the first time make sure the

following items are checked:

ELECTRICAL

Tank level sensor wires connected to distribution

box and sealed from moisture.

Tank level sensor functions properly.

Control cable connection at distribution box

correct and tight.

Flow sensor cable properly connected.

All cables and wires are secured and protected

from damage during operation.

Control and flow sensor cables properly folded

and secured; radio antennas, power lines and

equipment away from cables.

Foam pump and motor assembly properly

grounded using flat ground strap.

Correct voltage provided. Direct current,

negative (–) ground.

Adequate current, 40 AMPS minimum, available.

Main power direct to battery, battery switch or

solenoid without primer or other accessories

tied in.

Primary electrical and ground connections tight

and protected from corrosion with silicone

sealant.

Splices in wires sealed from moisture using

adhesive filled heat shrink tubing.

LIQUID

Flow sensor mounted with flow arrow in the

correct direction for water flow.

Check valves are properly mounted in water and

foam concentrate lines.

Strainer mounted for proper concentrate flow

direction in foam tank to pump hose.

Foam tank to foam pump valve is in place and

open.

Check valve/injector fitting lines are proper size

and connections are tight.

Bypass valve is properly mounted and oriented

for direction of concentrate flow.

Foam concentrate gravity feeds to foam pump

from foam concentrate tank.

All hoses free of kinks and sharp bends.

No sharp bends that can trap air exist in system.

Flush water connections correct and tight.

Discharge piping hydro tested in accordance

with NFPA/UL requirements.

Bypass valve handle is in the INJECT position.

FOAM PUMP

Foam pump and motor assembly mounted in

horizontal position with base plate down.

Foam pump and motor assembly properly

secured using proper mounting hardware.

Foam pump suction and discharge hoses

connected to proper ports.

Foam pump suction and discharge hose fittings

tight.