FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

43

ELECTRICAL INSTALLATION

Electrical Connections

Complete harness electrical diagrams are provided

on page 45 of this manual. Refer to these diagrams

for proper installation of each of the electrical

components.

The Hale FoamLogix system is designed to be

installed with a minimum of electrical connections.

Cables are provided with each Hale FoamLogix

system to make the flow sensor, control unit and

motor controller box connections.

The system installer must supply primary power

wire, low tank level sensor wire and flat braided

ground straps.

CAUTION!

Review the “Safety” section of this manual,

beginning on page 11, in its entirety before

proceeding with electrical connections.

To prevent system damage or electrical shock

the main power supply wire must be the last

connection made to the Hale FoamLogix motor

controller box. See Figure 3: “Typical Hale

FoamLogix 2.1A and 1.7APH System Layout” on

page 21.

The cables provided with each Hale FoamLogix

system contain shielded assemblies.

NEVER attempt to shorten or lengthen
the shielded cables. If necessary order
longer or shorter cables from Hale Products
to suit the particular installation.

The cables are indexed so they connect to the

correct receptacle one way only. When making

cable connections DO NOT force mismatched

connections as damage can result, causing

improper system operation.

The cables shipped with each Hale FoamLogix

system are tested at the factory with that unit.

Improper handling and forcing connections can

damage these cables which could result in other

system damage.

The system can only perform when the electrical

connections are sound. Make sure each electrical

connection is correct.

Hale FoamLogix systems are designed for use

on direct current, negative (–) ground apparatus

electrical systems only.

Do not mount radio transmitter or transmitter

cables in direct or close contact with the Hale

FoamLogix unit.

Before connecting the cables, inspect the O-ring

seal in the female connector. If the seal washer

is missing or damaged, water can enter the

connector causing corrosion of the pins and

terminals resulting in possible system failure.

The ground strap must be a minimum of 1-1/4”

(32mm) wide and no longer than 18” (457mm).

A longer ground strap must be wider or a
double thickness strap must be used. Make
sure the ground strap is attached to the
chassis frame. Grounding to the body IS NOT
acceptable.

Always disconnect the power cable, ground

straps, electrical wires and cables from the

control unit or other Hale FoamLogix equipment

before electric arc welding at any point on the

apparatus. Failure to do so could result in a

power surge through the unit that could cause

irreparable damage.

There are no user serviceable parts inside

Hale FoamLogix system electrical/ electronic

components. Opening of these components

(motor controller box or control unit) voids the

warranty.