General Maintenance

115

Model 6042

Origin 5/02

3. Remove dust from vacuator valve (Figure 68, 1) by squeezing bot-

tom of vacuator to allow loose particles to fall out. Replace ele-
ments, if required, as described in paragraph 2B.

Figure 68

B. Element: Change

(As Restriction Indicator Indicates or
250 Hour Intervals)

Outer Primary Element

All air cleaner manufacturers agree that attempting to clean or wash an
element increases the chance for element damage. It is highly
recommended that you consider the value of cleaning an element against
the risks which could lead to engine damage. Adopt the policy that all
elements should be replaced with new and not cleaned.

Inner Safety Element

An inner safety element should never be washed or reused. Always install a
new element. Replace inner safety elements after every third primary
element change. DO NOT remove an inner safety element until you have
thoroughly cleaned the inside of the air cleaner canister. This will prevent
dirt, which could damage the engine, from entering the induction manifold.

CAUTION:

NEVER run the engine with only the inner safety

element installed. Severe engine damage will result from dust
entering the engine.