Part ll - hydraulic line failure, Figure 60, Emergency operations – SkyTrak 6042 Operation Manual User Manual

Page 95

Advertising
background image

Emergency Operations

93

Model 6042

Origin 5/02

Part ll - Hydraulic Line Failure

In case of hydraulic line failure, there are step-by-step procedures available
to assist you in safely retracting and then lowering the boom. Read Part II
from start to finish before performing any of these procedures so you fully
understand the process and the danger involved. If you are unsure about
any part of these procedures contact your local OmniQuip Authorized
Service Center (ASC) or the OmniQuip Service Department.

Every attempt should be made to repair the hydraulic line failure and to
retract and then lower the boom in its normal fashion. We realize this is not
always possible. Step-by-step procedures are also available when the boom
must be retracted and lowered immediately and replacement parts are not
available. Only resort to Steps 3 & 4 (refer to table on page 94) when
absolutely necessary.

IMPORTANT! Be aware that the boom must first be retracted and then
lowered to avoid vehicle tipover.

In any case of hydraulic line failure, it is critical to correctly identify which
hydraulic line (Figure 60) has failed. Identify the hydraulic line that has
failed: Boom Retract line (1), Boom Extend line (2), Boom Lift line (3) and
Boom Lower line (4). Use the table on page 94 to determine which Step to
follow to retract and lower the boom.

Figure 60

2

OA1560

1

3

4

4

3

Advertising