Appendix a sonartractm gvf-100 specifications, Appendix a sonartrac, Gvf-100 specifications a1 physical specifications – CiDRA GVF-100 Gas Volume Fraction Monitoring System User Manual

Page 104

Advertising
background image

Copyright © 2006 CiDRA Corporation

Page A-1

20639-01 Rev 03

Appendix A SONARtrac

TM

GVF-100 SPECIFICATIONS

A1 Physical

Specifications

A1.1 Power

Supply

AC Voltage Version: 100 to 240 Volts AC, 50/60 Hz, 25 watts

DC Voltage Version: 18-36 Volts DC, 25 watts

A1.2 Fuse

Protection

AC Voltage Version: The transmitter input power is fuse protected by
two 1 amp, 250 volt, 5mm x 20mm fuses.

DC Voltage Version: The transmitter input power is fuse protected by
two 3.15 amp, 250 volt, 5mm x 20mm fuses.

A1.3

Operating Temperature Range

Transmitter

-4°F to +140°F (-20°C to +60°C)

Sensor Head Process Temperature

-40°F to +212°F (-40°C to +100°C)

Sensor Head Ambient Temperature

-40°F to +140°F (-40°C to +60°C)

A1.4 Storage

Temperature

Range

Transmitter

-22°F to +176°F (-30°C to +80°C)

Sensor Head

-40°F to +185°F (-40°C to +85°C)

A1.5 Construction

Materials

Sensor Head

Fiberglass enclosure with PTFE gasket material for sizes 2 to 16 inch

Stainless steel enclosure with silicone end seals for sizes 18 inch and
above

Transmitter

Fiberglass enclosure with NEMA 4X rating.

Urethane gasket material.

Acrylic viewing window.