2 operating transmitter display, 1 line 1 / line 2, 2 status line – CiDRA GVF-100 Gas Volume Fraction Monitoring System User Manual

Page 60: Figure 52 operating transmitter display -9, 7 ft/s

Advertising
background image

Copyright © 2006 CiDRA Corporation

Page 9-9

20639-01 Rev 03

9.5.1.2 Operating

Transmitter

Display

In operating mode the display screen is split into three distinct
portions. The majority of the screen is devoted to a 2-line
measurement display as illustrated below. The bottom portion of the
screen will display status and configuration information.

Figure 52

Operating Transmitter Display

9.5.1.2.1

Line 1 / Line 2

Either line may be configured to display any of the values listed below.

Value Units

Gas Volume Fraction

Percent (%)s

Speed Of Sound

Feet per Second (fps) or Meters per Second (mps)

Blank

Line is blank

Table 7

Line 1 and Line 2 Values

9.5.1.2.2 Status

Line

The code for information in the status line shown in Figure 52 are
defined as follows:

ID Characters Description

Values

S

20

Status Messages

See Status Messages Table below

Q

11

Quality Field

See Quality Field Message Table below

M

4

Mode

See Operating Mode Message Table below

C

1

Communications

E – Ethernet or S – Serial

H

1

Hart Activity

H – Hart Message received or [blank] – No Activity

W

1

Write Protect

W – Write Protected or
[blank] – Not Write Protected

E

1

Event Log Updated

! – Event Log Updated or [blank] – No change to
Event Log since last check

A

1

Activity

|/-\ (Cycle changes indicate activity)

Table 8

Status Line Code

G

V

F

2.016 %

S

O

S

351.7 ft/s

SSSSSSSSSSSSSSSSSSSS QQQQQQQQQQQ

MMMM

CHWEA

Gas Volume
Fraction

Speed Of
Sound

Line 1

Line 2

Status Line