1 bulkhead mounting, 2 pipe mounting, 1 bulkhead – CiDRA GVF-100 Gas Volume Fraction Monitoring System User Manual

Page 41: Mounting -2, 2 pipe

Advertising
background image

Copyright © 2006 CiDRA Corporation

Page 8-2

20639-01 Rev 03

8.3.1 Bulkhead

Mounting

The transmitter is attached to the bulkhead or panel with user supplied
1/4-inch fasteners through the four panel mounting feet on the
transmitter. The mounting dimensions are illustrated in the following
figure.

Figure 29

Bulkhead Mount Hole Pattern

8.3.2 Pipe

Mounting

The optional Pipe Mount Kit is designed to allow for mounting the
transmitter assembly to pipes up to 10-inch (250 mm) diameter and
equivalent sized I-beams. The kit consists of two mounting rails, two
band clamps, and fasteners. (Additional lengths of clamps can be
added for larger diameter pipes and I-beams. Please contact your
local distributor or CiDRA Corporation for more information.)

Figure 30

Pole Mount Kit

Attach the mounting rails to the panel mounting feet using the 1/4-20 x
3/4” screws and locknuts supplied with the rails. Slide the band
clamps through the slots in the mounting rails as shown. Wrap the
clamp around the pipe and feed the band through the clamp and
tighten. Excess band material can be removed if desired.

Panel mount feet
(4 places)

4X 0.31 (8) slot

11.88
(302)

14.22
(361)

4X 0.19 (5) slot

8.00
(203)

Note: Dimensions
in inches (mm)

Advertising