Page 9-18

20639-01 Rev 03

Level 1

Level 2

Level 3

Range

Description

Units

PSIg, None, F, C, Barg,
kPag

Parameter input

Scale

0.0000 e-38 to
9.9999 e+38 per mA

Input range divided by
mA range

Sensor #1

Offset

0.0000 e-38 to
9.9999 e+38 per mA

Correction due to a non-
zero mA minimum
output

Units

PSIg, None, F, C, Barg,
kPag

Parameter input

Scale

0.0000 e-38 to
9.9999 e+38 per mA

Input range divided by
mA range

Input Config

Sensor #2

Offset

0.0000 e-38 to
9.9999 e+38 per mA

Correction due to a non-
zero mA minimum
output