Feedback sensor specifications – ElmoMC Gold Line Digital Servo Drives-Gold Trombone User Manual

Page 15

Advertising
background image

Gold Trombone Installation Guide (EtherCAT and CAN)

Product Description

MAN-G-TROIG-EC (Ver. 1.604)

www.elmomc.com

15

2.2.6.

Feedback Sensor Specifications

Incremental Encoder – up to 75 Megacounts per second (18 MHz PPS(Pulses Per Second))

Digital Halls:

Up to 4 kHz commutation frequency

5 V logic

Input voltage up to 15 VDC

Incremental encoder with digital Halls for commutation – up to 75 Megacounts per second

for encoder

Interpolated Analog (Sine/Cosine) Encoder:

Supports 1 V PTP Sin/Cos

Sin/Cos frequency: up to 500 kHz

Internal interpolation: up to ×8192

Automatic correction of amplitude mismatch, phase mismatch, signal offset

Emulated encoder output of the analog encoder

Analog Hall Sensor:

One feedback electrical cycle = one electrical cycle of the motor

Supports 1 V PTP Sin/Cos

Sin/Cos Frequency: up to 500 kHz

Internal Interpolation: up to ×8192

Automatic correction of amplitude mismatch, phase mismatch, signal offset

Resolver

14 bit resolution

Up to 512 revolutions per second (RPS)

Emulated encoder outputs of the resolver

Auxiliary encoder inputs (ECAM, follower, etc.) single-ended, unbuffered

Tachometer & Potentiometer

Absolute serial encoders:

NRZ (Panasonic, Tamagawa, Mitutoyo, etc.)

EnDAT 2.2

BiSS/SSI

The Gold Trombone can provide power (5 V, 2x200 mA max) for encoders, resolver or Halls.

Advertising