4.10.2. Digital Outputs (J1)

The outputs conform to the PLC standard. TTL configuration is available upon request.

Pin (J1) Signal

Function

22

OUT1

High speed programmable digital output 1:

500 mA for PLC models

7 mA for TTL models

21

OUT2

Programmable digital output 2:

250 mA for PLC models

7 mA for TTL models

24

OUT3

Programmable digital output 3:

250 mA for PLC models

7 mA for TTL models

23

OUT4

Programmable digital output 4:

250 mA for PLC models

7 mA for TTL models

26

VDD

Supply for outputs 1 to 4

25

VDDRET

Supply return for outputs 1 to 4

Table 17: Digital Output Pin Assignment