16

2.2.7.

Communications

Fast and efficient EtherCAT and CAN networking

EtherCAT Slave per part number:

CoE (CAN over EtherCAT)

EoE (Ethernet over EtherCAT)

FoE (File over EtherCAT) for firmware download

Supports Distributed Clock

EtherCAT cyclic modes supported down to a cycle time of 250 μs

CAN (DS-301, DS-305, DS-402) per part number. Refer to the section 4.11 for further details

Ethernet TCP/IP

UDP

Telnet

USB 2.0

2.2.8.

Safety

Approved IEC /EN 61800-5-1, Safety

Approved IEC/EN 61800-3, EMC

IEC 61800-5-2, Safe Torque Off (STO) with two STO inputs PLC level which can be

configured to 5 V logic (available on request)

UL 508C recognition

UL 60950 compliance

CE EMC compliance

2.2.9.

Digital Outputs

Four separate programmable high voltage digital outputs related to VDD and VDDRET:

TTL level: optically isolated sink and source

PLC: optically isolated source

Conforms to IEC 61131-2

Up to 30 VDC

High side logic (Source)

For S, 0 suffix, Digital Outputs 2,3,4 up to 250 mA

For T, 1 suffix, Digital Outputs 2,3,4 up to 7 mA

For S, 0 suffix, Digital Output 1 brake output: 500 mA

For T, 1 suffix, Digital Output 1: 7 mA

Short circuit protection

Thermal protection

Reverse polarity protection

The four outputs can be configured to 5 V Logic (available on request)