Auxiliary supply – ElmoMC Gold Line Digital Servo Drives-Gold Trombone User Manual

Page 22

Advertising
background image

Gold Trombone Installation Guide (EtherCAT and CAN)

Technical Information

MAN-G-TROIG-EC (Ver. 1.604)

www.elmomc.com

22

Note on current ratings:

The current ratings of the Gold Trombone are given in units of DC

amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS
(sinusoidal commutation) value is the DC value divided by 1.41.

3.1.1.

Auxiliary Supply

Feature

Details

Auxiliary power supply

Isolated DC source only

Auxiliary supply input voltage

18 VDC to 30 VDC

Auxiliary supply input power

< 4 VA (this includes the 5 V/200 mA load for the main
encoder only)
< 5.5 VA (this includes the 5 V/400 mA load on the main
encoder and feedback B)

Advertising