3.1. Technical Data

Feature

Units

12/400 16/400 R17/400 R22/400 8/800

12/800

R11/800 R16/800

Minimum supply

voltage

VDC

*For S or T type = 50

For 0 or 1 suffix type = 100

*For S or T type = 95

Nominal supply

voltage

VDC

325

560 for 400 VAC
680 for 480 VAC

Maximum supply

voltage

VDC

400

780

Maximum continuous

power output

W

Up to 10 kW of continuous qualitative power

Efficiency at rated

power (at nominal

conditions)

%

> 98

Auxiliary supply

voltage option

VDC

18 to 30 VDC (only in S or T type)

Auxiliary power

supply

VA

≤5 VA without external loading

≤8 VA with full external loading

Continuous current

limit (Ic) Amplitude

sinusoidal/DC

trapezoidal

commutation

A

12

16

17

22

8

12

11

16

Sinusoidal continuous

RMS current limit (Ic)

A

8.5

11.3

12

15.5

5.7

8.5

7.8

11.3

Peak current limit

A

2 x Ic

No peak

2 x Ic

No peak

Weight

g (oz)

300 g (10.6 oz)

Dimensions

mm

(in)

111 x 76 x 34 (4.37" x 3" x 1.34")

Digital in/Digital out/

Analog in

6/4/1

Mounting method

PCB Mounted

*See page 23 for details on the part number. The S or T suffix appears in models where there is a
24 V control supply. If there is an 0 or 1 suffix, the control power supply operates from the main