Chapter 5: installation, Hardware requirements, Ac input requirements – ElmoMC Gold Line Digital Servo Drives-Gold Tuba User Manual

Page 11: Recommended wire cross-sections (all models), Chapter 5, Installation

Advertising
background image

Gold Tuba Installation Guide

MAN-G-TUBIG-EC (Ver. 1.201)

|Hardware Requirements|

www.elmomc.com

11

Table of Contents

Chapter 5:

Installation

The Gold Tuba must be installed in a suitable environment and properly connected to its voltage
supplies and the motor.

5.1. Hardware Requirements

AC Input Requirements

Circuit Breakers & Contacts

Three-Phase Supply Voltage

Circuit breaker current rating

40 A Type C

Circuit breaker voltage rating

250 VAC / 480 VAC depending upon operating
AC voltage

Contactor

40 A

Recommended Wire Cross-Sections (All Models)

Feature

Connection

Details

Recommended Maximum Wire Gauge

30 A Model

40 A Model

AC input

AC1, AC2, AC3

14 AWG

12 AWG

Protective Earth

PE

14 AWG

12 AWG

Note:

The actual size is determined by the drive’s current model.