7.4. Auxiliary Power

Backup functionality is required to store control parameters in the event of a mains power outage.

Note that the Gold Tuba always requires an external 24 VDC power supply, regardless of whether or
not backup functionality is required.

See Section 7.3.3 for full details.

Pin

Function

Cable

VL+

+24 V Auxiliary Supply Input Positive

Auxiliary Power

VL-

24 V RET Auxiliary Supply Input Return

Auxiliary Power

Pin Positions

2-Pin Pluggable 3.81 mm Phoenix Connector

2-Pin Phoenix Plug-in

Connector

Connect the auxiliary 24 VDC power supply as described below.
To connect the 24 VDC power supply:
1.

Use a 24 AWG twisted pair shielded cable. The shield should have copper braid.

2.

The source of the 24VDC power supply must be isolated from the mains.

3.

For safety and EMI reasons, connect the return of the 24 VDC power supply to the closest

ground (PE) in the power supply side.

4.

Connect the cable shield to the closest ground (PE) near the power source.

5.

Before applying power, first verify that the polarity of the connection is correct.