3.1.1 Site Requirements
You can guarantee the safe operation of the Cello by ensuring that it is installed in an
appropriate environment.
Feature
Value
Ambient operating temperature
0 °C to 40 °C (32 °F to 104 °F)
Maximum operating altitude
2,000 m (6562 feet)
Maximum non-condensing humidity 90%
Operating area atmosphere
No flammable gases or vapors permitted in area
Models for extended environmental conditions are available.
Caution:
The Cello dissipates its heat by convection. The maximum operating ambient
temperature of 0 °C to 40 °C (32 °F to 104 °F) must not be exceeded.
3.1.2 Hardware Requirements
The components that you will need to install your Cello are:
Component
Connector
Described in Section
Drawing
Main Power Cable
VP+ PR
Motor Cable
M1 M2 M3
Backup Supply Cable
(if needed)
24V