3 installation, 1 before you begin, 1 site requirements – ElmoMC SimplIQ Digital Servo Drives-Cello Installation Guide User Manual

Page 15: 2 hardware requirements, Installation, Before you begin 3.1.1, Site requirements, Hardware requirements

Advertising
background image

Cello Installation Guide

MAN-CELIG (Ver. 1.602)

www.elmomc.com

15

3

Installation

The Cello must be installed in a suitable environment and properly connected to its voltage
supplies and the motor.

3.1 Before You Begin

3.1.1 Site Requirements

You can guarantee the safe operation of the Cello by ensuring that it is installed in an
appropriate environment.

Feature

Value

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Maximum operating altitude

2,000 m (6562 feet)

Maximum non-condensing humidity 90%
Operating area atmosphere

No flammable gases or vapors permitted in area

Models for extended environmental conditions are available.

Caution:

The Cello dissipates its heat by convection. The maximum operating ambient
temperature of 0 °C to 40 °C (32 °F to 104 °F) must not be exceeded.

3.1.2 Hardware Requirements

The components that you will need to install your Cello are:

Component

Connector

Described in Section

Drawing

Main Power Cable

VP+ PR

3.4.2.2

Motor Cable

M1 M2 M3

3.4.2.1

Backup Supply Cable
(if needed)

24V

3.4.3

Advertising