8 i/os, 1 digital input interfaces, I/os 4.8.1 – ElmoMC SimplIQ Digital Servo Drives-Cello Installation Guide User Manual

Page 67: Digital input interfaces

Advertising
background image

Cello Installation Guide

Technical Specifications

MAN-CELIG (Ver. 1.602)

www.elmomc.com

67

4.8 I/Os

The Cello has:

10 Digital Inputs

5 Digital Outputs

2 Analog Input

4.8.1 Digital Input Interfaces

Feature

Details

Type of input

Optically isolated
Single ended
PLC level

Input current

* I

in

= 2.2 mA for V

in

= 12 V

Input current for high speed

inputs

* I

in

= 4.4 mA for V

in

= 12 V

High-level input voltage

12 V < V

in

< 30 V, 24 V typical

Low-level input voltage

0 V < V

in

< 6.5 V

Minimum pulse width

> 4 x TS, where TS is sampling time

Execution time (all inputs):

the time from application of

voltage on input until execution

is complete

If input is set to one of the built-in functions — Home, Inhibit,

Hard Stop, Soft Stop, Hard and Soft Stop, Forward Limit,

Reverse Limit or Begin — execution is immediate upon

detection: 0 < T < 4 x TS
If input is set to General input, execution depends on

program. Typical execution time: ≅ 0.5 msec.

High-speed inputs - minimum

pulse width, in high-speed mode

(IN5 - IN6)

T < 5 µsec
Notes:
Home mode is high-speed mode and can be used for
fast capture and precise homing.
High speed input has a digital filter set to same value
as digital filter (EF) of main encoder.
Highest speed is achieved when turning on
optocouplers.

Advertising