2 led indicators safety unit in 103303, Led indicators safety unit in 103303, K1, k2 – EUCHNER AS-i Safety Monitor for 2 AS-i circuits User Manual

Page 36: K3, k4, As-i safety monitor for 2 as-i circuits

Advertising
background image

36

Subject to reasonable modifications due to technical advances

Id.-No.: 103336

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

AS-i Safety Monitor for 2 AS-i circuits

Electrical connection

7.8.2

LED indicators safety unit in 103303

The LED’s on the safety unit indicate:

1.Y1

Aux

2.Y1

K1

K3

1.Y2

2.Y2

K2

K4

2.13

+

24 V

2.Y1

0 V

+

1.13

2.Y2

1.Y2

2.14

+

4.14

+

1.14

1.Y1

3.14

Aux

24 V supply for the semiconductor outputs is present.

1Y.1, 1Y2, 2Y.1, 2Y.2

Input 1.Y1 (EDM 1/Start 1), 2.Y1 (EDM 2/Start 2), 1.Y2 (EDM 3/Start 3),
2.Y2 (EDM 4/Start 4) is turned on.

K1, K2

Contact sets 1.13, 1.14 (K1) resp. 2.13, 2.14 (K2) closed.

K3, K4

Auxiliary voltage is present on the semiconductor output 3.14 (K3) resp.14 (K4).