11.4

Diagnostics using Profile S-7.5.5

11.4.1

Binary data

11.4.2

Transparent input data

Channel 0 of the transparent input data describes the status of both AS-i circuits.
The upper 8 bits describe the status of the AS-i 2 circuit and the lower 8 bits that
of the AS-i 1 circuit.

In channel 1 and 2 the colors of the release circuits follow (at present only 2 are
used).

Information!

The old diagnostics for the Safety Monitor is no longer supported.

D3

D2

D1

D0

Monitor->
Master (input)

Serial
communication

Serial
communication

1: Output 2 either
turned off or
flashing green

1: Output 1 either
turned off or
flashing green

Master->
Monitor (output)

Change from 0 to
1 resets the fault
lamp AS-i 2

Change from 0 to
1 resets Circuit 1
fault lamp

Serial
communication

Serial
communication

Tab. 11-4.

Channel

2

15

2

14

2

13

2

12

2

11

2

10

2

9

2

8

0

AS-i circuit 2

AU

RD

YE

GN

UA

DA

EF

1

Status OSSD 4

Status OSSD 3

2

Status OSSD 8

Status OSSD 7

3

OSSD 8

OSSD 7

OSSD 6

OSSD 5

RF

YF

RF

YF

RF

YF

RF

YF

Tab. 11-5.

Channel

2

15

2

14

2

13

2

12

2

11

2

10

2

9

2

8

0

AS-i circuit 1

RD

YE

GN

UA

DA

EF

1

Status OSSD 2

Status OSSD 1

2

Status OSSD 6

Status OSSD 5

3

OSSD 4

OSSD 3

OSSD 2

OSSD 1

RF

YF

RF

YF

RF

YF

RF

YF

Tab. 11-6.