Input code seq – EUCHNER AS-i Safety Monitor for 2 AS-i circuits User Manual

Page 57

Advertising
background image

AS-i Safety Monitor for 2 AS-i circuits

Operation in advanced display mode

Subject to reasonable modifications due to technical advances

Id.-No.: 103336

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

57

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

The teach procedure was successful if after approx. 2 s an OK appears in the dis-
play.

Save with OK, or cancel the process by pressing ESC.

9.3.1.4

INPUT CODE SEQ.

Main Menu || AS-I SAFETY || TEACH CODES|| INPUT CODE SEQ. ||

This menu point allows you to directly enter the code sequence for a particular
AS-i safety slave. If the slave address is already indicated, you can directly enter
the sequence using the keys and then save or discard it.

To continue, enter the PIN and confirm with OK.

In the following menu you select the AS-i circuit.

After selecting the AS-i circuit the safe unit switches to configuration mode.

Then enter the code sequence.

If no error message is displayed, the teach procedure was successfully complet-
ed.

Use OK to save the entries and return to the previous menu. Use ESC to cancel
the procedure.

COUPLING SLAVE
SLAVE ADDR.

––1

ESC

[OK]

TEACH CODES
ENTER PIN
0000
OK

AS-I CIRCUIT 1
AS-i CIRCUIT 2

SLAVE ADDR ––
ENTER CODE 1
00000000
ESC OK