AS-i Safety Monitor for 2 AS-i circuits

Diagnostics for AS-i Monitor and networking using AS-i Master

Subject to reasonable modifications due to technical advances

Id.-No.: 103336

Issue date - 24.10.2008

EUCHNER GmbH + Co. KG

85

Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0 • Fax. +49/711/753316

Bit field coding for devices which are present:

The numbers indicate the position of the bit for the corresponding device.

0:

Device is not present

1:

Device is present

Coding for the states and colors

Byte

Meaning

1

Bit 0 0=Configuration mode, 1=protecting mode
Bit 3 ... 1 reserved, 0
Bit 4 State 1.Y1, EDM1 (0=open)
Bit 5 State 1.Y2, Start1 (0=open)
Bit 6 State 2.Y1, EDM2 (0=open)
Bit 7 State 2.Y2, Start2 (0=open)

2

Relay status, Output 1+2
Bit 3 ... 0 State Output 1, diag_pc.ossd[0].relay-state
Bit 7 ... 4 State Output 2, diag_pc.ossd[1].relay-state

3 ... 8

...

9

Relay status, Output 15+16
Bit 3 ... 0 State Output 15, diag_pc.ossd[14].relay-state
Bit 7 ... 4 State Output 16, diag_pc.ossd[15].relay-state

10

Bit field for devices which are present. Device 7..0

11 ... 40

...

41

Bit field for devices which are present. Device 248..255

42

Color - Device 1+2
Bit 3..0 Color Device 1, diag_pc.device[0].color
Bit 7..4 Color Device 2, diag_pc.device[1].color

43 ... 168

...

169

Device 255+256
Bit 3..0 Color Device 255, diag_pc.device[254].color
Bit 7..4 Color Device 256, diag_pc.device[255].color

Tab. 11-15.

Byte

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

1

7

6

5

4

3

2

1

0

2

15

14

13

12

11

10

9

8

32

255

254

253

252

251

250

249

248

Tab. 11-16.