4-12

Configuring the Network

Variable: nvoDigInput2

Format: SNVT_switch

Explanation: This Network Variable Output provides the status of drive
digital input 2 via Logic Status word bit 13 (see

Logic Status Word on

page C-2

).

Variable: nvoDrvFault

Format: SNVT_count

Explanation: This Network Variable Output provides the drive fault
code.

PowerFlex 40 Drive Parameter Equivalent: Parameter d007 - [Fault 1
Code]
PowerFlex 400 Drive Parameter Equivalent: Parameter b007 - [Fault
1 Code]

Variable: nvoGenRdData

Format: SNVT_count

Explanation: This Network Variable Output provides data from the
parameter number defined by nciGenRdAdr. Data size is 2 bytes.

Scaling: No scaling is performed and all data is presented in raw format.

Parameter Mapping: nciGenRdAdr

Digital Input 2 Status

nvoDigInput 2 Variable

Status

Value (%)

State

0.0

0

Input 2 Disabled

100.0

1

Input 2 Enabled

Drive Error

Generic Parameter Data