Appendix b, Adapter parameters, Parameter list – Rockwell Automation 22-COMM-L LonWorks Adapter User Manual

Page 59: Parameter, Meters, refer to, Badapter parameters, Appendix

Advertising
background image

Appendix

B

Adapter Parameters

Appendix B presents information about the adapter parameters.

Topic

Page

Parameter List

B-1

Parameter List

Parameter
No. Name and Description

Details

01

[Send Service Pin]
Broadcasts a LON Service Pin Message from
the Neuron Chip. This provides the Neuron ID.

An alternate method for providing the Neuron ID
is enter the ID number manually. The Neuron ID
can be viewed using Parameter 04 - [Neuron
ID]
.

Default:

0 = Ready

Values:

0 = Ready
1 = Send

Type:

Read/Write

Reset Required

No

02

[Neuron State]
Displays the state of the Neuron Chip.

Default:

Values:

0 = appl_uncnfg
1 = cnfg_online
2 = unknown
3 = cnfg_offline

Type:

Read Only

03

[Reset Module]
No action if set to “0 = Ready.” Resets the
adapter if set to “1 = Reset Module.” Restores
the adapter to its factory default settings if set to
“2 = Set Defaults.” This parameter is a
command. It will be reset to “0 = Ready” after the
command has been performed.

Default:

0 = Ready

Values

0 = Ready
1 = Reset Module
2 = Set Defaults

Type:

Read/Write

Reset Required:

No

04

[Neuron ID]
Displays the Neuron Chip ID (6 bytes).

Default:

Values:

0 = Neuron Chip ID

Type: Read

Only

!

ATTENTION: Risk of injury or equipment damage exists. If the adapter is
transmitting I/O that controls the drive, the drive may fault when you reset the
adapter. Determine how your drive will respond before resetting a connected
adapter.

Advertising