Specifications – Rockwell Automation 1336VT 5-300 AMP (2.2-160KW) User Manual
Page 28
Advertising
4
Chapter
4-1
Specifications
Operating Environment
Temperature:
Open rating (heat sink), 0 to + 40
°
C.
Open rating (chassis components), 0 to +50
°
C.
Enclosed rating (heat sink), 0 to + 40
°
C.
Enclosed rating (chassis components), 0 to +50
°
C.
Relative Humidity: 5 to 95% non-condensing –– all ratings.
Altitude:
3,300 feet (1,000 meters) maximum without derating.
Vibration:
0.006 inches (0.152 mm) displacement, 1G peak.
Shock:
15G peak for 11ms duration (
±
1.0ms).
Storage Environment
Temperature:
– 40 to +85
°
C –– all ratings.
Relative Humidity: 5 to 95% non-condensing –– all ratings.
Enclosure
Indicated by Catalog Number.
Open (IP00) –– all ratings.
NEMA Type 1 (IP20) –– all ratings.
Advertising