Specifications – Rockwell Automation 1336VT 5-300 AMP (2.2-160KW) User Manual

Page 28

Advertising
background image

4

Chapter

4-1

Specifications

Operating Environment

Temperature:

Open rating (heat sink), 0 to + 40

°

C.

Open rating (chassis components), 0 to +50

°

C.

Enclosed rating (heat sink), 0 to + 40

°

C.

Enclosed rating (chassis components), 0 to +50

°

C.

Relative Humidity: 5 to 95% non-condensing –– all ratings.

Altitude:

3,300 feet (1,000 meters) maximum without derating.

Vibration:

0.006 inches (0.152 mm) displacement, 1G peak.

Shock:

15G peak for 11ms duration (

±

1.0ms).

Storage Environment

Temperature:

– 40 to +85

°

C –– all ratings.

Relative Humidity: 5 to 95% non-condensing –– all ratings.

Enclosure

Indicated by Catalog Number.

Open (IP00) –– all ratings.

NEMA Type 1 (IP20) –– all ratings.