Fault Codes

Chapter 10

10-6

Positive Phase Transistor Short

Freq

P

R

A shorted drive transistor has been detected. Check drive output transistors,
both upper and lower portions of each transistor, for a shorted condition.

Precharge Open

Freq

P

R

An error has been detected in the precharge circuit that does not allow
precharge to occur. Check the precharge circuit.

Clear Jammed

Freq

P

R

A fault has been detected originating from the Base Driver/Power Supply
Board. Check all wire and cable connections to the Base Driver/Power
Supply Board. Replace the Base Driver/Power Supply Board if required.

PWM Check

Freq

P

R

A fault has been detected originating from the Base Driver/Power Supply
Board. Check all wire and cable connections to the Base Driver/Power
Supply Board. Replace the Base Driver/Power Supply Board if required.

Drive Reset

Freq

P

R

A fault has been detected originating from the Base Driver/Power Supply
Board. Check all wire and cable connections to the Base Driver/Power
Supply Board. Replace the Base Driver/Power Supply Board if required.