Maximum wire size and torque requirements – Rockwell Automation 1336VT 5-300 AMP (2.2-160KW) User Manual

Page 59

Advertising
background image

Wiring

Chapter 6

6-15

Terminal Block TB1 -

L1, L2, L3

240Ć300ĂAmp Power Wiring (cont.)

Input AC line Terminals L1, L2, L3 (

A,

B,

C) are not

sensitive.

Nominal input voltage is 380/415/460V AC

±

10%, 3

, 50/60 Hz.

Branch disconnect and short circuit protection is not part of the standard
1336VT and must be supplied by the user.

Maximum Wire Size and Torque Requirements

+DC and –DC

+DC and –DC

M1-M3

M1-M3

Power

Drive

Terminal Block

Terminal Block

Terminal Block

Terminal Block

Rating

Output

Wire

Maximum

Maximum

Maximum

Maximum

Code

Current

Group

n

Wire Size

C

Torque

c

Wire Size

a

Torque

Q

200

240 Amps

2

350 MCM

275 In-lbs

500 MCM

375 In-lbs

250

300 Amps

2

350 MCM

275 In-lbs

500 MCM

375 In-lbs

n

Wire group number chart, page 6-3.

C

185 mm

2

.

c

31.08 N-m.

a

240 mm

2

.

Q

42.38 N-m.

Use the following guidelines when selecting branch circuit protection.

240 Amp Drive

Fuse Size 400A

Fuse Type A4J, JJS or Equivalent

300 Amp Drive

Fuse Size 500A

Fuse Type A4J, JJS or Equivalent

Advertising