Rockwell Automation 1336VT 5-300 AMP (2.2-160KW) User Manual
Page 31
Specifications
Chapter 4
4-4
Output Power
Waveform:
Sine coded pulse width modulated waveform.
Voltage:
0 to applied input voltage, 380V AC, 415V AC, or 460V
AC (maximum output voltage cannot exceed applied input
voltage).
Frequency Range:
0 to 250Hz with programmable minimum and maximum
limits.
Frequency
Digital —
Resolution:
Preset speeds (serial interface or pulse train input) to
0.005Hz of set frequency within the minimum and
maximum limits.
Analog —
Equal divisions between minimum and maximum limits to
the nearest 0.005Hz as a function of signal type.
Local speed pot (MOD-FA2 only), 1003 divisions.
Remote speed pot (TB2, Terminals 1, 2 and 3), 633
divisions.
0 to 10V DC input (TB2, Terminals 4 and 5), 976
divisions.
4 to 20mA input (TB2, Terminals 4 and 6), 726 divisions.
Frequency
Digital Frequency Source: 0.0013% of set frequency,
Regulation:
0 to 40
°
C ambient temperature range.
Volts-per-Hertz:
Fully programmable.
– Minimum 1 to 14.3V/Hz through local programming.
– Wider ranges available through optional programming.