Download and upload settings, Download and upload settings -3 – Rockwell Automation 1746-BTM Barrel Temperature Control Module User Manual User Manual

Page 71

Advertising
background image

Publication 1746-UM010B-EN-P - April 2001

Sample Program 9-3

Download and Upload Settings

IMPORTANT

In this version of code you do not command M1/M0
file transfers thru N7:0, you will now use N7:12
(master command request).

Table 9.B Download and Upload Settings

Location

Description

N7:12/0

set will download the M1 configuration

N7:12/1

set will download the M0 auto tune information

N7:12/2

set will download the M0 PID information

N7:12/3

set will upload the M0 auto tune information

N7:12/4

set will upload the M0 PID information

Advertising